3.8 Proceedings Paper

Bayesian calibration of building energy models: Comparison of predictive accuracy using metered utility data of different temporal resolution

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.egypro.2017.07.322

关键词

Bayesian calibration; building energy modeling; temporal data resolution; smart meter; detached single-family house

资金

  1. EU [609127]
  2. EPSRC [EP/L024454/1] Funding Source: UKRI

向作者/读者索取更多资源

Modem smart meters in heating systems offer building energy data of high temporal resolution. Compared to the annually aggregated readings used for conventional billing, the continuous information flow from these smart meters can be made available as time series data containing monthly, daily or even hourly aggregated values. In this paper, the effect of different temporal aggregation levels of commercial smart meter data on building energy model (BEM) calibration is investigated. Four different aggregation levels of a training data set were applied for calibration of six BEM input parameters to set up a Gaussian process emulator of the physical system. The performance of the emulator was subsequently tested on an unseen validation data set. Results reveal a systematic pattern of increasing predictive accuracy as a function of increasing training data resolution. (C) 2017 The Authors. Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据