4.4 Article

In vivo biocompatibility and hemocompatibility of a polytetrafluoroethylene small diameter vascular graft modified with sulfonated silk fibroin

期刊

AMERICAN JOURNAL OF SURGERY
卷 213, 期 1, 页码 87-93

出版社

EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC
DOI: 10.1016/j.amjsurg.2016.04.005

关键词

Small diameter vascular graft; Silk fibroin; Plasma; Sulfonate; Expanded polytetrafluoroethylene; Rabbit model

类别

资金

  1. Key Induction Project of Science and Technology, Guangdong Province [2012B091100159]
  2. Project of Science and Technology, Guangdong Province [2013B021800156]

向作者/读者索取更多资源

Objective: To evaluate the biocompatibility and hemocompatibility of an enhanced polytetrafluoroethylene (ePTFE) graft modified with sulfonated silk fibroin (SF) and to compare the patency rate of the modified graft to that of the commercially available unmodified ePTFE graft in a rabbit model. Methods: Twelve SF-modified grafts were used to replace a section of the lower abdominal aortic artery in rabbits, and 10 unmodified ePTFE grafts were used as controls. The patency rates of these grafts were examined according to physical findings, ultrasonic examination, and scanning electron microscopy (SEM). Results: The patency rates of SF-modified ePTFE grafts on day 3, from day 4 to 3 months, and at 3 months were 100%, 91.7%, and 91.7%, respectively, and these values were higher than those for the unmodified grafts (60.0%, 33.3%, and 20.0%, respectively, with P = 0.029, 0.022, and 0.002, respectively). SEM images of grafts harvested 3 months postoperatively showed that approximately 84% of the inner surface of the SF-modified grafts was covered with endothelial cells growing longitudinally with extensive cell cell connections. In comparison, endothelial cells covered only approximately 11% of the inner lumen of the unmodified grafts, and the inner surface of these grafts was covered, with activated platelets, erythrocytes, and newly formed extracellular matrix. We also have developed a rabbit model to evaluate the patency rate of small diameter vessel graft by replacing the lower abdominal aortic artery with graft. Conclusion: The SF-modified eFTFE graft had a higher patency rate than the unmodified FTFE graft in vivo. In addition, replacement of the rabbit abdominal aortic artery represents a feasible and convenient model for evaluating the patency of small diameter vascular grafts. (C) 2016 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据