3.8 Article

Experimental study and analysis of air heating system using a parabolic trough solar collector

期刊

INTERNATIONAL JOURNAL OF AMBIENT ENERGY
卷 39, 期 2, 页码 143-146

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1080/01430750.2016.1269677

关键词

Air flow rate; air heating; fins; parabolic trough collector and reflector

向作者/读者索取更多资源

An experimental study of air heating system was carried out using a parabolic trough collector with a U-tube aluminium heat exchanger. An evacuated tube placed at the focal length of the parabolic trough collected the solar radiations reflected from the surface of parabolic trough. The air was used as a working fluid, which was heated by passing it through a U-shaped aluminium heat exchanger placed inside the evacuated tube. It was found that efficiency of the parabolic trough collector depends on the mass flow rate, solar intensity and use of fins. It was observed that by using fins at a high mass flow rate of 4.557 kg/h, the maximum temperature of 126 degrees C was achieved which is 13.27% more than the maximum temperature obtained without fins. Furthermore, for a low-mass-flow rate of 1.69 kg/h, the maximum temperature obtained was 149 degrees C.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据