Direct human breath analysis by secondary nano-electrospray ionization ultrahigh-resolution mass spectrometry: Importance of high mass resolution and mass accuracy

期刊

RAPID COMMUNICATIONS IN MASS SPECTROMETRY
卷 31, 期 3, 页码 301-308

出版社

WILEY
DOI: 10.1002/rcm.7794

关键词

-

资金

  1. Fundamental Research Funds for the Central Universities [21615457]
  2. Beijing Key Laboratory for Emerging Organic Contaminants Control

向作者/读者索取更多资源

RationaleDirect mass spectrometry (MS)-based methods make it possible to monitor the molecular compositions of hundreds of volatile organic compounds (VOCs) in exhaled human breath in real time. Mass resolution and mass accuracy play important roles for direct MS analysis, especially for the low-concentration isobaric compounds in non-target research. MethodsDirect detection of VOCs in exhaled breath of four healthy subjects (3 males and 1 female aged between 25 to 35years old) has been performed by using secondary nano-electrospray ionization mass spectrometry (Sec-nanoESI-UHRMS) at resolutions (R) of 15,000, 30,000, 60,000 and 120,000. ResultsFor some low-intensity isobaric ions, they could be distinguished only when R60,000, e.g., signals at m/z 96.9591 (sulfate/sulfuric acid), m/z 96.9687 (phosphate/phosphoric acid) and m/z 96.9756 ([C4H2O7S](-)), m/z 234.1161 ([C10H20O3NS](+)) and m/z 234.1338 ([C10H20O5N](+)), m/z 119.0686 (isotope of indole) and m/z 119.0705 (an interfering signal), respectively. At R 120,000, the mass errors were obtained from a set of reference ions, and the values were 0.6 mDa for ions detected in positive detection mode and in the range of -1.0-1.1 mDa for the negative mode. These mass errors were used to exclusively identify unknown compounds detected in the breath samples. By utilizing the present setup, besides the normal VOCs reported previously, we detected non-volatile species (sulfate/sulfuric acid, silicate/silicic acid, phosphate/phosphoric acid and nitrate/nitric acid), dichlorobenzene and an ammonium adduct ([(C2H6SiO)(6)+NH4](+)), which were ascribed to exhaled particles, indoor air pollution and an endogenous source, respectively. ConclusionsFor direct breath analysis, high mass resolution of 60,000 and mass errors of 1.0 mDa (absolute value) covering the mass range of interests (e.g., m/z 50-500) are necessary for the exploration and accurate identification of low-intensity unknown isobaric compounds in non-target research. Copyright (c) 2017 John Wiley & Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据