4.6 Article

Inside/outside the brain binary cavitation localization based on the lowpass filter effect of the skull on the harmonic content: a proof of concept study

期刊

PHYSICS IN MEDICINE AND BIOLOGY
卷 63, 期 13, 页码 -

出版社

IOP PUBLISHING LTD
DOI: 10.1088/1361-6560/aaca21

关键词

cavitation; transcranial brain therapy; blood-brain-barrier opening; thermal necrosis; binary localization of cavitation

资金

  1. Bettencourt Schueller Foundation
  2. LABEX WIFI (Laboratory of Excellence within the French Program 'Investments for the Future') [ANR-10-LABX-24, ANR-10-IDEX-0001-02 PSL]
  3. National Agency for Research [ANR-10-EQPX-15]

向作者/读者索取更多资源

Cavitation activity induced by ultrasound may occur during high intensity focused ultrasound (HIFU) treatment, due to bubble nucleation under high peak negative pressure, and during blood-brain-barrier (BBB) disruption, due to injected ultrasound contrast agents (UCAs). Such microbubble activity has to be monitored to assess the safety and efficiency of ultrasonic brain treatments. In this study, we aim at assessing whether cavitation occurs within cerebral tissue by binary discriminating cavitation activity originating from the inside or the outside of the skull. The results were obtained from both in vitro experiments mimicking BBB opening, by using UCA flow, and in vitro thermal necrosis in calf brain samples. The sonication was applied using a 1 MHz focused transducer and the acoustic response of the microbubbles was recorded with a wideband passive cavitation detector. The spectral content of the recorded signal was used to localize microbubble activity. Since the skull acts as a low pass filter, the ratio of high harmonics to low harmonics is lower for cavitation events located inside the skull compared to events outside the skull. Experiments showed that the ratio of the 5/2 ultraharmonic to the 1/2 subharmonic for binary localization cavitation activity achieves 100% sensitivity and specificity for both monkey and human skulls. The harmonic ratio of the fourth to the second harmonic provided 100% sensitivity and 96% and 46% specificity on a non-human primate for thermal necrosis and BBB opening, respectively. Nonetheless, the harmonic ratio remains promising for human applications, as the experiments showed 100% sensitivity and 100% specificity for both thermal necrosis and BBB opening through the human skull. The study requires further validation on a larger number of skull samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据