3.8 Proceedings Paper

Temperature Measurement of Wire Electrode in Wire EDM by Two-color Pyrometer

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.procir.2017.12.029

关键词

Wire electrical discharge machining; Wire electrode; Temperature; Two-color pyrometer; Optical fiber

资金

  1. Die and Mould Technology Promotion Foundation

向作者/读者索取更多资源

In wire electrical discharge machining (EDM), it is considered that one of the major reasons why the wire electrode breakage occurs is the increase of temperature of wire electrode during machining. This is because the increase of the temperature leads to the decrease in the mechanical strength of wire electrode. However, the temperature of wire electrode has not been directly measured because it is difficult to measure the temperature by conventional measuring methods such as a thermocouple. Therefore, in this study, a two-color pyrometer with an optical fiber was used in order to measure the wire temperature during wire EDM in mist. Experimental results showed that the temperature of the wire electrode could be measured by the two-color pyrometer if the temperature was higher than 100 degrees C. Wire EDM was performed using a mist nozzle, and the temperature measurement of the wire electrode was attempted. Experimental results showed that the output of the two-color pyrometer was not observed, which indicated that the temperature of the wire electrode was lower than 100 degrees C under the experimental conditions used in this study. (c) 2018 The Authors. Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据