4.2 Article

THE 'PULL' TECHNIQUE FOR REMOVAL OF PERITONEAL DIALYSIS CATHETERS: A CALL FOR RE-EVALUATION OF PRACTICE STANDARDS

期刊

PERITONEAL DIALYSIS INTERNATIONAL
卷 37, 期 2, 页码 225-229

出版社

MULTIMED INC
DOI: 10.3747/pdi.2016.00152

关键词

Peritoneal dialysis; Tenckhoff catheter; peritonitis; Dacron

向作者/读者索取更多资源

Background: The most commonly used peritoneal dialysis (PD) catheters have silicon tubing with attached Dacron cuffs. The current standard of care for PD catheter removal is by complete surgical dissection, withdrawing both the tubing and the cuffs. The intention is to avoid infection of any residual part of the catheter. We retrospectively analyzed our results with the alternative 'pull' technique, by which the silicon tube is pulled out, leaving the Dacron cuffs within the abdominal wall. This technique never gained popularity due to concern that the retained cuffs would get infected. Methods: We reviewed our experience from an 18-month period, between January 2014 and June 2015. There were 46 catheter removals in 40 patients. All the catheters were of the double-cuffed coiled Tenckhoff type (Covidien, Dublin, Ireland). Results: Of the 46 catheter removals by the 'pull' technique, there was only 1 case of retained cuff infection. Conclusions: The 'pull' technique is a safe method for Tenckhoff catheter removal with low risk of infection. We strongly recommend it as the procedure of choice.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据