ENERGY AND BUILDINGS
卷 108, 期 -, 页码 236-243出版社
ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2015.09.010
关键词
Historic building; Case study; Simulation; Monitoring; Calibration; Sensitivity analysis; Particle swarm optimization; EnergyPlus
资金
- European Union Seventh Framework Program (FP7), project 3ENCULT [260162]
Uncalibrated building energy models, as well as models calibrated only on a single performance indicator such as energy consumption or indoor temperature, can be significantly unreliable regarding model parameters and other performance indicators. The risk of obtaining a calibrated model whose parameters are far from the actual values is particularly high in historic buildings because of the increased uncertainty about the building construction. In this paper, we propose a calibration methodology aimed at reducing this risk and apply it on a medieval building. The building was modeled in EnergyPlus based on an energy audit. A sensitivity analysis was performed to identify significant parameters affecting the errors between simulated and monitored indoor air temperatures. The model was calibrated on the hourly indoor air temperatures in summer by minimizing the root mean square error averaged over the building using a particle swarm optimization algorithm. A second calibration was performed by varying the parameters of a representative room. By comparing the results from these two calibrations, we obtained indications about the accuracy of the model parameters. Finally, the model was validated on hourly indoor air and surface temperatures in winter where temperature root mean square errors ranged from 0.4 to 0.8 K. (C) 2015 The Authors. Published by Elsevier B.V.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据