4.5 Article

Opportunistic screening for osteoporosis by routine CT in Southern Europe

期刊

OSTEOPOROSIS INTERNATIONAL
卷 28, 期 3, 页码 983-990

出版社

SPRINGER LONDON LTD
DOI: 10.1007/s00198-016-3804-3

关键词

Bone density; Computed tomography; External validation; Lumbar vertebrae; Osteoporosis; Screening; Spinal fractures

资金

  1. Spanish Ministerio de Economia y Competitividad (MINECO)
  2. FEDER funds [TEC2012-33778, BFU2015-64380-C2-2-R]
  3. MINECO FPI

向作者/读者索取更多资源

Feasibility evaluation of early detection of osteoporosis in oncologic patients by bone mineral density (BMD) on abdominal computed tomography (CT) scans performed for other clinical indications, by using dual-energy X-ray absorptiometry (DXA) as reference. Abdominal CT images can identify patients with osteoporosis BMD without additional radiation exposure or cost. The purpose of the study is to evaluate the feasibility of early detection of osteoporosis by bone mineral density (BMD) on abdominal computed tomography (CT) scans performed in oncologic patients, comparing calibrated and uncalibrated measurements by using dual-energy X-ray absorptiometry (DXA) as reference. We also performed an external validation of a threshold of 160 Hounsfield units (HU), proposed as highly sensitive. Cohort comprised CT-DXA pairs within a 6-month period performed for any indication on 326 consecutive adults, aged 62.4 +/- 12.38 years (mean +/- standard deviation). CT attenuation of trabecular bone in HU was measured at the axial cross sections of L1, L2, L3, and L4 vertebrae. Vertebral compression fractures were assessed by sagittal reconstruction view. Diagnostic performance measures and the area under the receiver operator characteristic curve (AUC) for diagnosing osteoporosis were calculated. BMD values were statistical significantly lower at any vertebral level from L1 to L4 for patients with osteoporosis defined by DXA (p < 0.001). Calibrated and uncalibrated BMD values were significantly correlated (R (2) = 0.833, p < 0.01). An uncalibrated L1 CT attenuation threshold of 160 HU was more than 90 % sensitive, and a threshold of 73 HU was more than 90 % specific for distinguishing osteoporosis BMD. Fifty-nine percent of patients with vertebral compression fracture had non-osteoporotic DXA T-scores. Abdominal CT images obtained for other reasons can identify patients with osteoporosis BMD without additional radiation exposure or cost. Uncalibrated values at L1 can detect more osteoporosis patients with spinal compression fractures than DXA in oncologic patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据