4.3 Article

Pattern recognition and bionic manipulator driving by surface electromyography signals using convolutional neural network

出版社

SAGE PUBLICATIONS INC
DOI: 10.1177/1729881418802138

关键词

Surface electromyography; convolutional neural network; hand gesture classification; NinaPro database 5; bionic manipulator

类别

资金

  1. National Natural Science Foundation of China [51475034]

向作者/读者索取更多资源

With the development of robotics, intelligent neuroprosthesis for amputees is more concerned. Research of robot controlling based on electrocardiogram, electromyography, and electroencephalogram is a hot spot. In medical research, electrode arrays are commonly used as sensors for surface electromyograms. Although these sensors collect more accurate data and sampling at higher frequencies, they have no advantage in terms of portability and ease of use. In recent years, there are also some small surface electromyography sensors for research. The portability of the sensor and the calculation speed of the calculation method directly affect the development of the bionic prosthesis. A consumer-grade surface electromyography device is selected as surface electromyography sensor in this study. We first proposed a data structure to convert raw surface electromyography signals from an array structure into a matrix structure (we called it surface electromyography graph). Then, a convolutional neural network was used to classify it. Discrete surface electromyography signals recorded from three persons 14 gestures (widely used in other research to evaluate the performance of classifier) have been applied to train the classifier and we get an accuracy of 97.27%. The impacts of different components used in convolutional neural network were tested with this data, and subsequently, the best results were selected to build the classifier used in this article. The NinaPro database 5 (one of the biggest surface electromyography data sets) was also used to evaluate our method, which comprises of hand movement data of 10 intact subjects with two myo armbands as sensors, and the classification accuracy increased by 13.76% on average when using double myo armbands and increased by 18.92% on average when using single myo armband. In order to driving the robot hand (bionic manipulator), a group of continuous surface electromyography signals was recorded to train the classifier, and an accuracy of 91.72% was acquired. We also used the same method to collect a set of surface electromyography data from a disabled with hand lost, then classified it using the above mentioned network and achieved an accuracy of 89.37%. Finally, the classifier was deployed to the microcontroller to drive the bionic manipulator, and the full video URL is given in the conclusion, with both the healthy man and the disabled tested with the bionic manipulator. The abovementioned results suggest that this method will help to facilitate the development and application of surface electromyography neuroprosthesis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据