4.6 Article

The Application of Infrared Imaging and Optical Coherence Tomography of the Lacrimal Punctum in Patients Undergoing Punctoplasty for Epiphora

期刊

OPHTHALMOLOGY
卷 124, 期 6, 页码 910-917

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.ophtha.2017.01.054

关键词

-

资金

  1. Department of Health's NIHR Biomedical Research Centre for Ophthalmology at Moorfields Eye Hospital
  2. UCL Institute of Ophthalmology, London, United Kingdom
  3. Allergan
  4. National Institute for Health Research [CS-2014-14-023] Funding Source: researchfish

向作者/读者索取更多资源

Purpose: To determine the application of imaging the stenotic lacrimal punctum with infrared photographs and optical coherence tomography (OCT) and to identify characteristics of the lacrimal punctum in patients who benefit from punctoplasty. Design: Case-control study. Participants: Twenty patients with epiphora who were listed for punctoplasty and 20 healthy controls. Methods: Prospectively, 20 patients listed for punctoplasty were asked to rate their epiphora, using the Munk score, before and after punctoplasty. They also underwent preoperative OCT and infrared imaging of the affected punctum. They were divided into 2 groups, depending on whether the epiphora improved, and were compared with 20 healthy controls. Main Outcome Measures: Measurements of puncta from infrared and OCT images were obtained along with Munk scores of patient epiphora. Results: The infrared image measurements were significantly smaller in those patients whose epiphora improved compared with those whose did not in both the area of the punctal aperture and in the maximum punctal diameter. Additionally, those patients with improvement in epiphora had a significantly smaller preoperative punctal diameter at 100 mu m depth on OCT compared with healthy controls; this was not observed in patients whose epiphora failed to improve. There was no significant difference in the punctum diameter among the 3 groups at the punctum surface entrance or at 500 mu m depth. Patients with epiphora had a higher tear meniscus within the punctum compared with healthy controls. Conclusions: Lacrimal punctum infrared and OCT imaging may be helpful in predicting patients more likely to benefit symptomatically from punctoplasty, with patients with smaller puncta having greater symptomatic improvement. However, the results suggest that inner punctum diameter (not readily measurable by slit-lamp examination), rather than the surface diameter, is correlated with outcome. Additionally, OCT measurements of the tear meniscus height within the punctum may be related to the degree of epiphora. (C) 2017 by the American Academy of Ophthalmology

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据