3.8 Article

Determination of bacterial species present in biofilm contaminating the channels of clinical endoscopes

期刊

INFECTION DISEASE & HEALTH
卷 23, 期 4, 页码 189-196

出版社

ELSEVIER INC
DOI: 10.1016/j.idh.2018.06.003

关键词

Endoscopes; Decontamination; Microbiota; Biofilms; Cross infection; Infection control

资金

  1. Faculty of Medicine and Health Sciences, Macquarie University
  2. Australian Research Council Linkage Project Scheme [LP130100572]
  3. Whiteley Corporation
  4. Medical Services Department (MSD) of the Ministry of Defense and Aviation, Saudi Arabia
  5. Cotutelle International Macquarie University Research Excellence iMQRES scholarship
  6. Coordination for the Improvement of Higher Education Personnel Scholarship (CAPES)
  7. Macquarie University Vice Chancellor Innovation Fellowship
  8. Australian Research Council [LP130100572] Funding Source: Australian Research Council

向作者/读者索取更多资源

Background: Outbreaks of endoscopy-related Carbapenem-resistant Enterobacteriaceae has highlighted failures in endoscope decontamination resulting in biofilm formation. Biofilms are tolerant to detergents and disinfectants. We evaluated decontaminated endoscope channels for residual bacterial contamination and biofilm presence. Methods: 64 channels were collected from 12 gastroscopes and 11 colonoscopes. Aerobic bacteria were isolated from inside the endoscope tubing by scrapping, sonication, and aerobic plate culture. Total number of contaminating bacteria was determined by quantitative real-time PCR with 16s rRNA eubacterial universal primers. Microbial diversity was assessed using next generation DNA sequencing. Biofilm presence was visually confirmed by confocal laser scanning and scanning electron microscopy. Results: 47% of channels were culture positive, with alpha-haemolytic Streptococci from gastroscopes and coliforms from colonoscopes the most frequently isolated species. Sphingomonas spp., Staphylococcus spp., Streptococcus spp., and Pseudomonas aeruginosa were also isolated. An average of 1.2 x 10(3) bacteria/cm contaminated air-water channels, 2.8 x 10(2) and 6.6 x 10(2) bacteria/cm contaminated gastroscope and colonoscope working channels, respectively. Biofilm was on all 39 channels examined and was principally composed of environmental bacteria, although all samples contained potential pathogens. Conclusion: Biofilm is present on many endoscope channels obtained from Australian hospitals. Any soil including biofilm can compromise disinfectant action. (C) 2018 Australasian College for Infection Prevention and Control. Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据