Effect of second hardening on floor response spectrum of a base-isolated nuclear power plant

期刊

NUCLEAR ENGINEERING AND DESIGN
卷 322, 期 -, 页码 138-147

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.nucengdes.2017.06.004

关键词

Floor response spectrum; Second hardening; Nuclear power plant; Base isolation; Lead rubber bearing

资金

  1. Korea Institute of Energy Technology Evaluation and Planning (KETEP) - Ministry of Trade, Industry & Energy, Republic of Korea [2011T100200080]
  2. Korea Ministry of Land, Infrastructure and Transport (MOLIT)

向作者/读者索取更多资源

The floor response spectra are calculated by constructing a numerical model (APR1400) equipped with base isolators of a bilinear material and a Bouc-Wen material, respectively, in order to investigate the effect of the second hardening. The variations of the earthquakes are incorporated to the loads, and two different properties of the isolator materials are modeled. The second hardening behavior increases the stiffness of the isolator in the high strain regime and suppresses the displacement of the isolator. Therefore, the role of the base isolation device isolating the superstructure from the ground motion does not perform properly, which causes amplification of the floor response of the superstructure. In practice, the second hardening of the isolator material might need to be taken into account for designing the base isolation system. (C) 2017 Published by Elsevier B.V.