4.0 Article Proceedings Paper

Validity and reproducibility of retinal arteriole and venule diameter measurements: ELSA-Brasil study. A cross-sectional study

期刊

SAO PAULO MEDICAL JOURNAL
卷 136, 期 4, 页码 276-286

出版社

ASSOCIACAO PAULISTA MEDICINA
DOI: 10.1590/1516-3180.2018.0227230718

关键词

Microvessels; Retinal artery; Retinal vein; Reproducibility of results

资金

  1. Brazilian Ministry of Health (Science and Technology Department)
  2. Brazilian Ministry of Science and Technology
  3. Brazilian Ministry of Science and Technology (National Council for Scientific and Technological Development, CNPq) [01 06 0010.00 RS, 0106 0212.00 BA, 01 06 0300.00 ES, 0106 0278.00 MG, 01 06 0115.00 SP, 01 06 0071.00 RJ]
  4. Coordination Office for the Improvement of Higher-Education Personnel (CAPES) [1503609]

向作者/读者索取更多资源

BACKGROUND: Investigation of alterations to retinal microvasculature may contribute towards understanding the role of such changes in the pathophysiology of several chronic non-communicable diseases. The objective here was to evaluate the validity and reproducibility of retinal arteriole and venule diameter measurements made by Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) graders. DESIGN AND SETTING: Cross-sectional study at six teaching and research institutions. METHODS: To evaluate validity, each of 25 retinal images from the University of Wisconsin (gold standard) was measured by five ELSA-Brasil graders. To evaluate reproducibility, 105 images across the spectrum of vessel diameters were selected from 12,257 retinal images that had been obtained between 2010 and 2012, and each image was reexamined by the same grader and by an independent grader. All measurements were made using the Interactive Vessel Analysis (IVAN) software. Bland-Altman plots, paired t tests and intraclass correlation coefficients (ICCs) were analyzed. RESULTS: Mean differences between ELSA-Brasil and gold-standard readings were 0.16 mu m (95% CI -0.17-0.50; P = 0.31) for central retinal artery equivalent (CRAE), -0.21 mu m (95% CI -0.56-0.14; P = 0.22) for central retinal vein equivalent (CRVE) and 0.0005 (95% CI -0.008-0.009; P = 0.55) for arteriole/venule ratio (AVR). Intragrader ICCs were 0.77 (95% CI 0.67-0.86) for CRAE, 0.90 (95% CI 0.780.96) for CRVE and 0.70 (0.55-0.83) for AVR. Intergrader ICCs were 0.75 (95% CI 0.64-0.85) for CRAE, 0.90 (95% CI 0.79-0.96) for CRVE and 0.68 (95% CI 0.55-0.82) for AVR. CONCLUSIONS: Retinal microvascular diameter measurements are valid and present moderate to high intra and intergrader reproducibility in ELSA-Brasil.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据