期刊
CSEE JOURNAL OF POWER AND ENERGY SYSTEMS
卷 4, 期 4, 页码 425-433出版社
CHINA ELECTRIC POWER RESEARCH INST
DOI: 10.17775/CSEEJPES.2018.00320
关键词
Electricity-heat integrated energy system; heat pump; Monte Carlo simulation; reliability evaluation; security constraints
资金
- Shanghai Sailing Program [18YF1411600]
- National Key R&D Program of China [2018YFB0905000]
Integrated energy system (IES) has the advantages of improving the efficiency of energy utilization and promoting the consumption of renewable energy. It is of great importance to evaluate the reliability of an IES. This paper proposes a novel reliability evaluation method for the electricity-heat IES with heat pump. First, the load-point reliability indices and system-level reliability indices are defined according to the characteristics of electricity-heat IES. Second, the model of maximum output heat power of heat pump at the user-side considering the safety criterion of distribution network is established, and the step-varied repeated power flow method is applied to solve the model. Third, the reliability evaluation procedure of electricity-heat IES with heat pump based on the Monte Carlo simulation is presented. Case studies are carried out on the electricity-heat IES of an industrial park, and the results show that the configuration site, capacity and coefficient of performance of heat pump as well as the security constraints of distribution network can significantly affect the reliability indices.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐