4.3 Article

Subsequent Pulse Generator Replacement Surgery Does Not Increase the Infection Rate in Patients With Deep Brain Stimulator Systems: A Review of 1537 Unique Implants at a Single Center

期刊

NEUROMODULATION
卷 20, 期 5, 页码 444-449

出版社

WILEY
DOI: 10.1111/ner.12605

关键词

Complications; deep brain stimulation; implant; infection; internal pulse generator

向作者/读者索取更多资源

IntroductionDeep brain stimulation (DBS) is a well-recognized treatment for patients with movement disorders and other neurological diseases. The implantable pulse generator (IPG) is a fundamental component of the DBS system. Although IPG implantation and replacement surgeries are comparatively minor procedures relative to the brain lead insertion, patients often require multiple IPG replacements during their lifetime with each operation carrying a small but possibly cumulative risk of complications. To better educate our patients and improve surgical outcomes, we reviewed our series of patients at our institution. MethodsUsing electronic health record data, we retrospectively reviewed all initial and subsequent IPG surgeries from patients who underwent at least one IPG surgery between the years of 2010 and 2015 at the Cleveland Clinic main campus. We calculated infection rates for initial IPG implantation surgeries and the infection rate for subsequent replacements. Fisher's exact tests were used to evaluate the chance of an infection between the initial implantation and replacement. Fisher's exact tests and simple logistic regression analyses were used to determine the predictive ability of selected demographic and clinical variables ResultsOur final sample included 697 patients and 1537 surgeries. For all patients, the infection rate at the first surgery was 2.01%; at the second surgery, it was 0.44%; and at the third surgery, it was 1.83%. When considering only patients that underwent at least three replacement surgeries (n=114) the infection rate did not change in a significant manner with subsequent interventions compared to the first replacement. No other variable of interest was a significant predictor of infection. ConclusionWe did not find increasing rates of infection with subsequent IPG replacement procedures.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据