4.0 Article

Assessing the prevalence of protein-energy wasting in haemodialysis patients: A cross-sectional monocentric study

期刊

NEPHROLOGIE & THERAPEUTIQUE
卷 13, 期 7, 页码 537-543

出版社

ELSEVIER MASSON, CORPORATION OFFICE
DOI: 10.1016/j.nephro.2017.02.013

关键词

Albumin; Chronic kidney disease; Dietary intake; Nutritional assessment; Prealbumin; Protein-energy intake

资金

  1. National Centre for Scientific and Technique research (CNRST)

向作者/读者索取更多资源

Introduction. - Protein-energy wasting (PEW) is a strong predictive factor for morbidity and mortality in haemodialysis (HD) patients. However, there is no consensus for its assessment. The present study aimed to assess the nutritional status of patients on chronic HD by use of different nutritional assessment parameters, and at verifying which can identify the greatest number of HD patients with PEW. Also, to investigate predictors of nutritional status in a haemodialysis center in Morocco. Patients and methods. - This is a cross-sectional analysis performed on 126 patients aged 44.82 +/- 14.01 years, undergoing maintenance HD in the Department of nephrology of the university hospital centre of Casablanca, Morocco. Energy and nutrients intake assessment was obtained by a three-day period food recall. Biochemical parameters, bioelectric impedance analysis, and subjective global assessment (SGA), have been performed to assess nutritional status. Results. - According to SGA the prevalence of PEW was 74.62%. However, when using the ISRMN malnutrition criteria only 36.50% of the patients were diagnosed with PEW. Pearson correlation showed a negative association between the degree of malnutrition evaluated by SGA and serum prealbumin (r = -0.54; P = 0.0001), serum albumin (r = -0.50; P = 0.001), energy (r = -0.34; P = 0.002), protein intake (r=-0.41; P=0.0001), and a significant positive correlation with CRP (r=0.65; P=0.0001) was determined, but not with anthropometric measurements nor lipids profile. The areas under the receiver operating characteristic curve were 0.841 (95% CI: 0.751-0.932) for serum prealbumin, and 0.737 (95% CI: 0.634-0.840) for serum albumin. Conclusion. - Our results showed a high prevalence of PEW among Haemodialysis patients. Also, our findings suggest that SGA, serum albumin and prealbumin may be relative appropriate and practical markers for assessing nutritional status in HD patients. (C) 2017 Societe francophone de nephrologie, dialyse et transplantation. Published by Elsevier Masson SAS. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据