4.7 Article

Optimization of a Protease Activated Probe for Optical Surgical Navigation

期刊

MOLECULAR PHARMACEUTICS
卷 15, 期 3, 页码 750-758

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.molpharmaceut.7b00822

关键词

optical contrast agents; fluorescently quenched probes; fluorescence guided surgery

资金

  1. NIH [R01 CA179253, R01 GM111703]
  2. DFG [TH2139/1-1]
  3. Stanford ChEM-H Chemistry/Biology Interface Predoctoral Training Program
  4. NSF [DGE-114747]

向作者/读者索取更多资源

Molecularly targeted optical contrast agents have the potential to enable surgeons to visualize specific molecular markers that can help improve surgical precision and thus outcomes. Fluorescently quenched substrates can be used to highlight tumor lesions by targeting proteases that are highly abundant in the tumor microenvironment. However, the majority of these and other molecularly targeted optical contrast agents are labeled with reporter dyes that are not ideally matched to the properties of clinical camera systems, which are typically optimized for detection of indocyanine-green (ICG). While a wide range of near-infrared (NIR) dyes are suitable for use with highly sensitive and highly tunable research-focused small animal imaging systems, most have not been evaluated for use with commonly used clinical imaging systems. Here we report the optimization of a small molecule fluorescently quenched protease substrate probe 6QC-ICG, which uses the indocyanine green (ICG) dye as its optical reporter. We evaluated dosing and kinetic parameters of this molecule in tumor-bearing mice and observed optimal tumor over background signals in as little as 90 min with a dose of 2.3 mg/kg. Importantly, the fluorescence intensity of the probe signal in tumors did not linearly scale with dose, suggesting the importance of detailed dosing studies. Furthermore, when imaged using the FDA approved da Vinci Si surgical system with Firefly detection, signals were significantly higher for the ICG probe compared to a corresponding probe containing a dye with similar quantum yield but with a slightly shifted excitation and emission profile. The increased signal intensity generated by the optimal dye and dose of the ICG labeled probe enabled detection of small, flat lesions that were less than 5 mm in diameter. Therefore, 6QC-ICG is a highly sensitive probe that performs optimally with clinical imaging systems and has great potential for applications in optical surgical navigation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据