Sequential determination of cadmium and lead in organic pharmaceutical formulations using high-resolution continuum source graphite furnace atomic absorption spectrometry

期刊

MICROCHEMICAL JOURNAL
卷 130, 期 -, 页码 157-161

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.microc.2016.09.001

关键词

Cadmium; Lead; Sequential determination; HR CS GFAAS; Pharmaceutical formulations; Factorial design

资金

  1. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)
  2. PRONEX/Fundacao de Amparo a Pesquisa do Estado da Bahia (FAPESB)
  3. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)

向作者/读者索取更多资源

This paper proposes a method using high resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) for the sequential determination of cadmium and lead in organic pharmaceutical formulations. The temperature program for cadmium was established employing the pyrolysis and atomization temperatures of 800 degrees C and 1400 degrees C, respectively, and the atomization temperature of 2000 degrees C for lead, being that the pyrolysis temperature for lead is the same used for the cadmium atomization. The analytical measures were performed using the primary lines for cadmium (228.802 nm) and (217.001 nm) for lead. The absorbance signals obtained were quantified by peak area using 3 pixels for both analytes, utilizing as chemical modifier an acid mixture palladium-magnesium. Employing the optimized conditions, the method allows the sequential determination of cadmium and lead, with limits of detection and quantification of 4 and 13 ng g(-1) for cadmium and 49 and 165 ng g(-1) for lead, respectively. The characteristics masses were also calculated, being 1.6 pg for cadmium and 12.4 pg for lead. The precision expressed as relative standard deviation (%RSD) were 5.0% for cadmium and 6.2% for lead, determined by ten replicates of a sample solution with cadmium and lead contents of 38 and 303 ng g(-1), respectively. The method accuracy was evaluated and confirmed by analysis of two certified reference materials of leaves furnished by National Institute of Standards and Technology (NIST). Furthermore, addition/recovery tests were also performed using three different real samples. The recoveries obtained varied from 94 to 114%, it confirming the method accuracy. The method was applied for the determination of cadmium and lead in ten different pharmaceutical formulations and the analyte concentrations found in the samples varied from 16 to 51 ng g(-1) for cadmium and of 179 to 318 ng g(-1) for lead, being that for six samples the lead contents were lower than the limit of quantification (165 ng g(-1)) and for three samples the cadmium concentrations were lower than 13 ng g(-1). All samples were also analyzed employing inductively coupled plasma mass spectrometry (ICP-MS) and the results obtained are agreement with those achieved by HR CS GFAAS. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据