4.5 Article

Optimal fiducial points for pulse rate variability analysis from forehead and finger photoplethysmographic signals

期刊

PHYSIOLOGICAL MEASUREMENT
卷 40, 期 2, 页码 -

出版社

IOP PUBLISHING LTD
DOI: 10.1088/1361-6579/ab009b

关键词

photoplethysmography (PPG); ECG; heart rate variability; pulse rate variability; autonomic nervous system; fiducial point selection; transmission and reflection modes

资金

  1. Ministerio de Economia, Industria y Competitividad (MINECO)
  2. fondos FEDER [RTI2018-097723-B-I00]
  3. Government of Aragon
  4. European Social Fund (EU) through Grupo de Referencia BSICoS [T39 17R]
  5. University of Zaragoza [UZ2018-TEC-05]
  6. CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) through Instituto de Salud Carlos III
  7. Research Council of Lithuania [S-MIP-17/81]
  8. European Union Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Skodowska-Curie Grant [745755]

向作者/读者索取更多资源

Objective: The aim of this work is to evaluate and compare five fiducial points for the temporal location of each pulse wave from forehead and finger photoplethysmographic (PPG) pulse wave signals to perform pulse rate variability (PRV) analysis as a surrogate for heart rate variability (HRV) analysis. Approach: Forehead and finger PPG signals were recorded during a tilt-table test simultaneously with the electrocardiogram (ECG). Artefacts were detected and removed and five fiducial points were computed: apex, middle-amplitude and foot points of the PPG signal, apex point of the first derivative signal and the intersection point of the tangent to the PPG waveform at the apex of the derivative PPG signal and the tangent to the foot of the PPG pulse, defined as the intersecting tangents method. Pulse period (PP) time interval series were obtained from both PPG signals and compared with the RR intervals obtained from the ECG. HRV and PRV signals were estimated and classical time and frequency domain indices were computed. Main results: The middle-amplitude point of the PPG signal (n(M)), the apex point of the first derivative (n(A)*), and the tangent intersection point (n(T)) are the most suitable fiducial points for PRV analysis, resulting in the lowest relative errors estimated between PRV and HRV indices and higher correlation coefficients and reliability indices. Statistically significant differences according to the Wilcoxon test between PRV and HRV signals were found for the apex and foot fiducial points of the PPG, as well as the lowest agreement between RR and PP series according to Bland-Altman analysis. Hence, these signals have been considered less accurate for variability analysis. In addition, the relative errors are significantly lower for n(M) and n(A)(*) using Friedman statistics with a Bonferroni multiple-comparison test, and we propose that n(M) is the most accurate fiducial point. Based on our results, forehead PPG seems to provide more reliable information for a PRV assessment than finger PPG. Significance: The accuracy of the pulse wave detection depends on the morphology of the PPG. There is therefore a need to widely define the most accurate fiducial point for performing a PRV analysis under non-stationary conditions based on different PPG sensor locations and signal acquisition techniques.