4.5 Article

Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations Updated guidelines for reporting parallel group randomized trials

期刊

MEDICINE
卷 96, 期 25, 页码 -

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MD.0000000000007239

关键词

absolute humidity; anesthesia machine; humidification; temperature

资金

  1. Korea Health Technology R&D Project through the Korea Health Industry Development Institute
  2. Ministry of Health and Welfare, Republic of Korea [HI13C2181]

向作者/读者索取更多资源

Background: For patients undergoing general anesthesia, adequate warming and humidification of the inspired gases is very important. The aim of this study was to evaluate the differences in the heat and moisture content of the inspired gases with low-flow anesthesia using 4 different anesthesia machines. Methods: The patients were divided into 11 groups according to the anesthesia machine used (Ohmeda, Excel; Avance; Drager, Cato; and Primus) and the fresh gas flow (FGF) rate (0.5, 1, and 4L/min). The temperature and absolute humidity of the inspired gas in the inspiratory limbs were measured at 5, 10, 15, 30, 45, 60, 75, 90, 105, and 120 minutes in 9 patients scheduled for total thyroidectomy or cervical spine operation in each group. Results: The anesthesia machines of Excel, Avance, Cato, and Primus did not show statistically significant changes in the inspired gas temperatures over time within each group with various FGFs. They, however, showed statistically significant changes in the absolute humidity of the inspired gas over time within each group with low FGF anesthesia (P<.05). The anesthesia machines of Cato and Primus showed statistically significant changes in the absolute humidity of the inspired gas over time within each group with an FGF of 4L/min (P<.05). However, even with low-flow anesthesia, the temperatures and absolute humidities of the inspired gas for all anesthesia machines were lower than the recommended values. Conclusion: There were statistical differences in the provision of humidity among different anesthesia workstations. The Cato and Primus workstations were superior to Excel and Avance. However, even these were unsatisfactory in humans. Therefore, additional devices that provide inspired gases with adequate heat and humidity are needed for those undergoing general anesthetic procedures.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据