4.6 Article

A sensitive and regenerative electrochemical immunosensor for quantitative detection of Escherichia coli O157:H7 based on stable polyaniline coated screen-printed carbon electrode and rGO-NR-Au@Pt

期刊

ANALYTICAL METHODS
卷 11, 期 11, 页码 1475-1482

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c8ay02594k

关键词

-

资金

  1. National Natural Science Foundation of Zhejiang Province [LY17C200003]
  2. Food and Engineering most important discipline of Zhejiang province [2017SIAR210, JYTSP20141062]
  3. Zhejiang public Innovation Platform Analysis and testing project [2018C37056]
  4. technology innovation activities (acrobatic tender grass talent program) project [1110KZN0217054P, 1110KZN0217053P]
  5. State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital of Medical College, Zhejiang University [2017KF02]
  6. Plans of college students in Zhejiang province

向作者/读者索取更多资源

A sensitive and quantitative sandwich electrochemical immunosensor was constructed for the detection of Escherichia coli O157:H7 (E. coli O157: H7) using immune gold@platinum nanoparticles (Au@Pt), neutral red (NR), reduced graphene oxide nanocomposite (rGO) and regenerative leucoemeraldine base polyaniline (PANI)/gold nanoparticles (AuNPs) modified screen-printed carbon electrode (SPCE). The batch production advantages of the SPCE were retained, its disposable characteristic was replaced by the possibility for reuse. The anti-E. coli O157:H7 monoclonal antibody (Ab1) was automatically adsorbed on the SPCE-PANI-AuNPs platform through the amino and AuNPs interaction. rGO-NR-Au@Pt as the non-enzyme signal label can enhance the performance of the immunoassay for the catalytic reduction of H2O2 and amplify the current signal. All characterization steps were monitored by cyclic voltammetry (CV). Based on electrochemical detection of E. coli O157:H7, the linear range was from 8.9 x 10(3) to 8.9 x 10(9) CFU mL(-1), and limit of detection (LOD) was 2.84 x 10(3) CFU mL(-1). To ensure that the immunosensor can be used repeatedly, ultrasound sonication was used to remove as many surface-bound antibodies as possible. This allows Ab1 to bind to the SPCE-PANI-AuNPs again after the electrode was re-incubated with the antibody solution, and hence, the displacement assay can be repeated and the sensor reused. Furthermore, it was demonstrated that the microchips can be regenerated and reused at least 5 times.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据