4.5 Article

Fast and reproducible in vivo T1 mapping of the human cervical spinal cord

期刊

MAGNETIC RESONANCE IN MEDICINE
卷 79, 期 4, 页码 2142-2148

出版社

WILEY
DOI: 10.1002/mrm.26852

关键词

spinal cord; reduced FOV; T-1 mapping; reproducibility; inversion Recovery

资金

  1. UK MS Society
  2. UCL-UCLH Biomedical Research Centre
  3. Horizon2020-EU3.1 CDS-QUAMRI [634541]
  4. Guarantors of Brain Project
  5. MRC [MR/J500422/1, MR/J01107X/1]
  6. NIHR BRC UCLH/UCL High Impact Initiative [BW.mn.BRC10269]
  7. EPSRC [EP/H046410/1, EP/J020990/1, EP/K005278]
  8. Wings for Life
  9. Spinal Research
  10. Craig H. Neilsen Foundation
  11. [EPSRC EP/I027084/1]
  12. [ISRT IMG006]
  13. EPSRC [EP/I027084/1, EP/M020533/1, EP/N018702/1, EP/J020990/1, EP/H046410/1, EP/G007748/1] Funding Source: UKRI
  14. MRC [MR/M009106/1] Funding Source: UKRI
  15. Engineering and Physical Sciences Research Council [EP/H046410/1, EP/N018702/1, EP/G007748/1, EP/J020990/1] Funding Source: researchfish
  16. Medical Research Council [MR/M009106/1, MR/J01107X/1] Funding Source: researchfish

向作者/读者索取更多资源

PurposeTo develop a fast and robust method for measuring T-1 in the whole cervical spinal cord in vivo, and to assess its reproducibility. MethodsA spatially nonselective adiabatic inversion pulse is combined with zonally oblique-magnified multislice echo-planar imaging to produce a reduced field-of-view inversion-recovery echo-planar imaging protocol. Multi- inversion time data are obtained by cycling slice order throughout sequence repetitions. Measurement of T-1 is performed using 12 inversion times for a total protocol duration of 7min. Reproducibility of regional T-1 estimates is assessed in a scan-rescan experiment on five heathy subjects. ResultsRegional mean (standard deviation) T-1 was: 1108.5 (77.2) ms for left lateral column, 1110.1 (+/- 83.2) ms for right lateral column, 1150.4 (+/- 102.6) ms for dorsal column, and 1136.4 (+/- 90.8) ms for gray matter. Regional T-1 estimates showed good correlation between sessions (Pearson correlation coefficient=0.89 (P value<0.01); mean difference=2 ms, 95% confidence interval +/- 20 ms); and high reproducibility (intersession coefficient of variation approximately 1% in all the regions considered, intraclass correlation coefficient=0.88 (P value<0.01, confidence interval 0.71-0.95)). ConclusionsT(1) estimates in the cervical spinal cord are reproducible using inversion-recovery zonally oblique-magnified multislice echo-planar imaging. The short acquisition time and large coverage of this method paves the way for accurate T-1 mapping for various spinal cord pathologies. Magn Reson Med 79:2142-2148, 2018. (c) 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据