4.5 Article

High-resolution in vivo diffusion imaging of the human brain with generalized slice dithered enhanced resolution: Simultaneous multislice (gSlider-SMS)

期刊

MAGNETIC RESONANCE IN MEDICINE
卷 79, 期 1, 页码 141-151

出版社

WILEY
DOI: 10.1002/mrm.26653

关键词

diffusion imaging; simultaneous multislice; slice encoding; simultaneous multislab

资金

  1. NIH NIBIB [R01EB020613, R24MH106096, R01EB019437, K99EB021349, R00EB015445, S10-RR023401, S10-RR023043, S10-RR019307]
  2. NATIONAL CENTER FOR RESEARCH RESOURCES [S10RR019307, S10RR023043, S10RR023401] Funding Source: NIH RePORTER
  3. NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING [R00EB021349, R00EB015445, R01EB020613, P41EB015896, K99EB021349, R01EB019437] Funding Source: NIH RePORTER
  4. NATIONAL INSTITUTE OF MENTAL HEALTH [R24MH106096] Funding Source: NIH RePORTER
  5. NATIONAL INSTITUTE OF NEUROLOGICAL DISORDERS AND STROKE [K23NS096056] Funding Source: NIH RePORTER

向作者/读者索取更多资源

PurposeTo develop an efficient acquisition for high-resolution diffusion imaging and allow in vivo whole-brain acquisitions at 600- to 700-m isotropic resolution. MethodsWe combine blipped-controlled aliasing in parallel imaging simultaneous multislice (SMS) with a novel slab radiofrequency (RF) encoding gSlider (generalized slice-dithered enhanced resolution) to form a signal-to-noise ratio-efficient volumetric simultaneous multislab acquisition. Here, multiple thin slabs are acquired simultaneously with controlled aliasing, and unaliased with parallel imaging. To achieve high resolution in the slice direction, the slab is volumetrically encoded using RF encoding with a scheme similar to Hadamard encoding. However, with gSlider, the RF-encoding bases are specifically designed to be highly independent and provide high image signal-to-noise ratio in each slab acquisition to enable self-navigation of the diffusion's phase corruption. Finally, the method is combined with zoomed imaging (while retaining whole-brain coverage) to facilitate low-distortion single-shot in-plane encoding with echo-planar imaging at high resolution. ResultsA 10-slices-per-shot gSlider-SMS acquisition was used to acquire whole-brain data at 660 and 760 m isotropic resolution with b-values of 1500 and 1800 s/mm(2), respectively. Data were acquired on the Connectome 3 Tesla scanner with 64-channel head coil. High-quality data with excellent contrast were achieved at these resolutions, which enable the visualization of fine-scale structures. ConclusionsThe gSlider-SMS approach provides a new, efficient way to acquire high-resolution diffusion data. Magn Reson Med 79:141-151, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据