4.5 Article

CFD Model of Particle Agglomeration in Spray Drying

期刊

DRYING TECHNOLOGY
卷 33, 期 15-16, 页码 1971-1980

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/07373937.2015.1081605

关键词

CFD; Counter-current spray drying; Droplet drying model; Particle agglomeration model

向作者/读者索取更多资源

A 3D CFD model of the agglomeration of droplets and particles in a counter-current spray-drying process was developed and verified. An original discrete phase model was elaborated, with an agglomeration module taking into account hydrodynamic segregation of particles, droplet coalescence, and droplet shrinkage for accurate calculations of mass balance of the discrete phase. The characteristic drying curves were applied to the model of particle moisture evaporation, which included the coupling of particle agglomeration with heat, mass, and momentum transfer between the discrete and continuous phases. Two agglomeration zones were observed in the tower: wet particle agglomeration in the atomization zone, and dry agglomeration above the air inlets, due to the intensive mixing of particle streams. A comparison of the calculated particle size distributions and experimental data obtained from particle dynamics analysis (PDA) measurements proves the accuracy of the developed methodology. The elaborated model allows the final PSD of the powder in the spray towers to be predicted.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据