4.7 Article

Implant and Midterm Outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry The EFFORTLESS Study

期刊

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2017.06.040

关键词

-

资金

  1. Boston Scientific Corporation
  2. Cardiology Department for Medtronic
  3. Boston Scientific
  4. Medtronic
  5. St. Jude Medical
  6. University College London Hospitals Biomedicine National Institute of Health Research

向作者/读者索取更多资源

BACKGROUND The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to defibrillate ventricular arrhythmias, avoiding drawbacks of transvenous leads. The global EFFORTLESS S-ICD (Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD) registry is collecting outcomes in 985 patients during a 5-year follow-up. OBJECTIVES The primary goal of the EFFORTLESS registry is to determine the safety of the S-ICD by evaluating complications and inappropriate shock rate. METHODS This is the first report on the full patient cohort and study endpoints with follow-up >= 1 year. The predefined endpoints are 30- and 360-day complications, and shocks for atrial fibrillation or supraventricular tachycardia. RESULTS Patients were followed for 3.1 +/- 1.5 years and 82 completed the study protocol 5-year visit. Average age was 48 years, 28% were women, ejection fraction was 43 +/- 18%, and 65% had a primary prevention indication. The S-ICD system and procedure complication rate was 4.1% at 30 days and 8.4% at 360 days. The 1-year complication rate trended toward improvement from the first to last quartile of enrollment (11.3% [quartile 1]) to 7.8% [quartile 2], 6.6% [quartile 3], and 7.4% [quartile 4]; quartile 1 vs. quartiles 2 to 4; p = 0.06). Few device extractions occurred due to need for antitachycardia (n = 5), or biventricular (n = 4) or bradycardia pacing (n = 1). Inappropriate shocks occurred in 8.1% at 1 year and 11.7% after 3.1 years. At implant, 99.5% of patients had a successful conversion of induced ventricular tachycardia or ventricular fibrillation. The 1- and 5-year rates of appropriate shock were 5.8% and 13.5%, respectively. Conversion success for discrete spontaneous episodes was 97.4% overall. CONCLUSIONS This registry demonstrates that the S-ICD fulfills predefined endpoints for safety and efficacy. Midterm performance rates on complications, inappropriate shocks, and conversion efficacy were comparable to rates observed in transvenous implantable cardioverter-defibrillator studies. (C) 2017 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据