4.7 Article

AF Ablation Guided by Spatiotemporal Electrogram Dispersion Without Pulmonary Vein Isolation A Wholly Patient-Tailored Approach

期刊

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2016.10.065

关键词

cycle length; dispersion driver; fractionated; mapping; sinus rhythm

资金

  1. St. Jude Medical
  2. Medtronic
  3. [15K09077]
  4. [15KK0341]

向作者/读者索取更多资源

BACKGROUND The use of intracardiac electrograms to guide atrial fibrillation (AF) ablation has yielded conflicting results. OBJECTIVES The authors evaluated the usefulness of spatiotemporal dispersion, a visually recognizable electric footprint of AF drivers, for the ablation of all forms of AF. METHODS The authors prospectively enrolled 105 patients admitted for AF ablation. AF was sequentially mapped in both atria with a 20-pole PentaRay catheter. The authors tagged and ablated only regions displaying electrogram dispersion during AF. Results were compared to a validation set in which a conventional ablation approach was used (pulmonary vein isolation/stepwise approach). To establish the mechanism underlying spatiotemporal dispersion of AF electrograms, the authors conducted realistic numerical simulations of AF drivers in a 2-dimensional model and optical mapping of ovine atrial scar-related AF. RESULTS Ablation at dispersion areas terminated AF in 95% of the 105 patients. After ablation of 17 +/- 10% of the left atrial surface and 18 months of follow-up, the atrial arrhythmia recurrence rate was 15% after 1.4 +/- 0.5 procedures per patient versus 41% in the validation set after 1.5 +/- 0.5 procedures per patient (arrhythmia free-survival: 85% vs. 59%; log-rank p < 0.001). Compared with the validation set, radiofrequency times (49 +/- 21 min vs. 85 +/- 34.5 min; p = 0.001) and procedure times (168 +/- 42 min vs. 230 +/- 67 min; p < 0.0001) were shorter. In simulations and optical mapping experiments, virtual PentaRay recordings demonstrated that electrogram dispersion is mostly recorded in the vicinity of a driver. CONCLUSIONS The clustering of intracardiac electrograms exhibiting spatiotemporal dispersion is indicative of AF drivers. Their ablation allows for a nonextensive and patient-tailored approach to AF ablation. (Substrate Ablation Guided by High Density Mapping in Atrial Fibrillation [SUBSTRATE HD]; NCT02093949) (C) 2017 by the American College of Cardiology Foundation. Published by Elsevier. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据