4.7 Article

Association of Titin-Truncating Genetic Variants With Life-threatening Cardiac Arrhythmias in Patients With Dilated Cardiomyopathy and Implanted Defibrillators

期刊

JAMA NETWORK OPEN
卷 2, 期 6, 页码 -

出版社

AMER MEDICAL ASSOC
DOI: 10.1001/jamanetworkopen.2019.6520

关键词

-

资金

  1. Wellcome Trust
  2. UK Department of Health
  3. UK National Institute for Health Research Cardiovascular Biomedical Research Unit at Royal Brompton and Harefield National Health Service Foundation Trust and Imperial College London
  4. British Heart Foundation
  5. Foundation Leducq
  6. UK Medical Research Council intramural funding
  7. MRC [MC_U120085815, MR/M003191/1, MC_UP_1102/20, 1964807] Funding Source: UKRI

向作者/读者索取更多资源

IMPORTANCE There is a need for better arrhythmic risk stratification in nonischemic dilated cardiomyopathy (DCM). Titin-truncating variants (TTNtvs) in the TTN gene are the most common genetic cause of DCM and may be associated with higher risk of arrhythmias in patients with DCM. OBJECTIVE To determine if TTNtv status is associated with the development of life-threatening ventricular arrhythmia and new persistent atrial fibrillation in patients with DCM and implanted cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) devices. DESIGN, SETTING, AND PARTICIPANTS This retrospective, multicenter cohort study recruited 148 patients with or without TTNtvs who had nonischemic DCM and ICD or CRT-D devices from secondary and tertiary cardiology clinics in the United Kingdom from February 1, 2011, to June 30, 2016, with a median (interquartile range) follow-up of 4.2 (2.1-6.5) years. Exclusion criteria were ischemic cardiomyopathy, primary valve disease, congenital heart disease, or a known or likely pathogenic variant in the lamin A/C gene. Analyses were performed February 1, 2017, to May 31, 2017. MAIN OUTCOME AND MEASURES The primary outcome was time to first device-treated ventricular tachycardia of more than 200 beats/min or first device-treated ventricular fibrillation. Secondary outcome measures included time to first development of persistent atrial fibrillation. RESULTS Of 148 patients recruited, 117 adult patients with nonischemic DCM and an ICD or CRT-D device (mean [SD] age, 56.9 [12.5] years; 76 [65.0%] men; 106 patients [90.6%] with primary prevention indications) were included. Having a TTNtv was associated with a higher risk of receiving appropriate ICD therapy (shock or antitachycardia pacing) for ventricular tachycardia or fibrillation (hazard ratio [HR], 4.9; 95% CI, 2.2-10.7; P<.001). This association was independent of all covariates, including midwall fibrosis measured by late gadolinium enhancement on cardiac magnetic resonance images (adjusted HR, 8.3; 95% CI, 1.8-37.6; P=.006). Having a TTNtv was also associated with the risk of receiving a shock (HR, 3.6; 95% CI, 1.1-11.6; P=.03). Individuals with a TTNtv and fibrosis had a greater rate of receiving appropriate device therapy than those with neither (HR, 16.6; 95% CI, 3.5-79.3; P<.001). Having a TTNtv was also a risk factor for developing new persistent atrial fibrillation (HR, 3.9; 95% CI, 1.3-12.0; P=.01). CONCLUSIONS AND RELEVANCE Having a TTNtv was an important risk factor for clinically significant arrhythmia in patients with DCM and ICD or CRT-D devices. Having a TTNtv, especially in combination with midwall fibrosis confirmed with cardiovascular magnetic resonance imaging, may provide a risk stratification approach for evaluating the need for ICD therapy in patients with DCM. This hypothesis should be tested in larger studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据