Efficient 3D-CTF correction for cryo-electron tomography using NovaCTF improves subtomogram averaging resolution to 3.4 Å

期刊

JOURNAL OF STRUCTURAL BIOLOGY
卷 199, 期 3, 页码 187-195

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.jsb.2017.07.007

关键词

Cryo-electron microscopy; Tomography; Contrast transfer function; Subtomogram averaging; Defocus; Reconstruction; Weighted back projection

资金

  1. Deutsche Forschungsgemeinschaft [BR 3635/2-1]
  2. European Research Council (ERC) under the European Union's Horizon research and innovation programme [ERC-CoG-648432 MEMBRANEFUSION]
  3. European Molecular Biology Laboratory
  4. Chica and Heinz Schaller Stiftung
  5. MRC [MC_UP_1201/16] Funding Source: UKRI
  6. Medical Research Council [MC_UP_1201/16] Funding Source: researchfish

向作者/读者索取更多资源

Cryo-electron tomography (cryo-ET) allows cellular ultrastructures and macromolecular complexes to be imaged in three-dimensions in their native environments. Cryo-electron tomograms are reconstructed from projection images taken at defined tilt-angles. In order to recover high-resolution information from cryo-electron tomograms, it is necessary to measure and correct for the contrast transfer function (CTF) of the microscope. Most commonly, this is performed using protocols that approximate the sample as a two-dimensional (2D) plane. This approximation accounts for differences in defocus and therefore CTF across the tilted sample. It does not account for differences in defocus of objects at different heights within the sample; instead, a 3D approach is required. Currently available approaches for 3D-CTF correction are computationally expensive and have not been widely implemented. Here we simulate the benefits of 3D-CTF correction for high-resolution subtomogram averaging, and present a user-friendly, computationally-efficient 3D-CTF correction tool, NovaCTF, that is compatible with standard tomogram reconstruction workflows in IMOD. We validate the approach on synthetic data and test it using subtomogram averaging of real data. Consistent with our simulations, we find that 3D-CTF correction allows high-resolution structures to be obtained with much smaller subtomogram averaging datasets than are required using 2D-CTF. We also show that using equivalent dataset sizes, 3D-CTF correction can be used to obtain higher-resolution structures. We present a 3.4 angstrom resolution structure determined by subtomogram averaging.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据