VALIDITY AND RELIABILITY OF A PORTABLE ISOMETRIC MID-THIGH CLEAN PULL

期刊

JOURNAL OF STRENGTH AND CONDITIONING RESEARCH
卷 31, 期 5, 页码 1378-1386

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1519/JSC.0000000000001201

关键词

peak force; rate of force development; field testing; strength; force-time curve

向作者/读者索取更多资源

This study investigated the test-retest reliability and criterion validity of force-time curve variables collected through a portable isometric mid-thigh clean pull (IMTP) device equipped with a single-axial load cell. Fifteen males with >= 6 months of resistance training experience attended two testing sessions. In each session, participants performed an IMTP in 2 separate conditions in a randomized counterbalanced manner. The criterion condition consisted of a closed-chain IMTP configured with a force plate (IMTPf), whereas the experimental test was undertaken using a portable IMTP with data acquired through a single-axial load cell (IMTPl). A very high reliability (coefficient of variation [CV] = 3.10, 90% confidence interval [CI]: 2.4-4.6%; intraclass correlation coefficient [ICC] = 0.96, 90% CI: 0.90-0.98) and acceptable validity (CV = 9.2, 90% CI: 7-14%; ICC = 0.88, 90% CI: 0.71-0.95) were found in the experimental condition for the measure of peak force. However, significant differences were present between the IMTPf and IMTPl (p < 0.0001). Alternate force-time curve variables did not reach acceptable levels of validity or reliability in the experimental condition. The IMTPl is a valid and highly reliable method for assessing peak force. This provides evidence supporting the use of an IMTPl as a cost-effective and portable alternative for those who wish to assess maximal force production in a similar fashion to a traditional IMTP. However, practitioners should be aware that these are slightly different tests.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据