PSEUDO-CT GENERATION FOR MRI-ONLY RADIOTHERAPY: COMPARATIVE STUDY BETWEEN A GENERATIVE ADVERSARIAL NETWORK, A U-NET NETWORK, A PATCH-BASED, AND AN ATLAS BASED METHODS

出版社

IEEE
DOI: 10.1109/isbi.2019.8759278

关键词

Pseudo-CT; Magnetic Resonance Imaging; Radiotherapy Treatment Planning

向作者/读者索取更多资源

As new radiotherapy treatment systems using MRI (rather than traditional CT) are being developed, the accurate calculation of dose maps from MR imaging has become an increasing concern. MRI provides good soft-tissue but, unlike CT, lacks the electron density information necessary for dose calculation. In this paper, we proposed a generative adversarial network (GAN) using a perceptual loss to generate pseudo-CTs for prostate MRI dose calculation. This network was evaluated and compared to a U-Net network, a patch-based (PBM) and an atlas-based methods (ARM). Influence of the perceptual loss was assessed by comparing this network to a GAN using a L2 loss. GANs and U-Nets are rather similar with slightly better results for GANs. The proposed GAN outperformed the PBM by 9% and the ARM by 13% in term of MAE in whole pelvis. This method could be used for online dose calculation in MRI-only radiotherapy.