4.5 Article

Optimization of a DPI Inhaler: A Computational Approach

期刊

JOURNAL OF PHARMACEUTICAL SCIENCES
卷 106, 期 3, 页码 850-858

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.xphs.2016.11.008

关键词

simulations; dispersion; powder technology; oral drug delivery; particle size; mathematical model; microparticles

向作者/读者索取更多资源

Alternate geometries of a commercial dry powder inhaler (DPI, i.e., Turbuhaler; AstraZeneca, London, UK) are proposed based on the simulation results obtained from a fluid and particle dynamic computational model, previously developed by Milenkovic et al. The alternate DPI geometries are constructed by simple alterations to components of the commercial inhaler device leading to smoother flow patterns in regions where significant particle-wall collisions occur. The modified DPIs are investigated under the same conditions of the original studies of Milenkovic et al. for a wide range of inhalation flow rates (i.e., 30-70 L/min). Based on the computational results in terms of total particle deposition and fine particle fraction, the modified DPIs were improved over the original design of the commercial device. (C) 2017 American Pharmacists Association (R). Published by Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据