4.6 Article

Enhancing analysis throughput, sensitivity and specificity in LC/ESI-MS/MS assay of plasma 25-hydroxyvitamin D3 by derivatization with triplex 4-(4-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione (DAPTAD) isotopologues

期刊

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpba.2016.11.030

关键词

LC/ESI-MS/MS; Derivatization; Isotopologue; Analysis throughput; Vitamin D

资金

  1. JSPS KAKENHI [26460043]
  2. Grants-in-Aid for Scientific Research [26460043, 17K08250] Funding Source: KAKEN

向作者/读者索取更多资源

The plasma/serum concentration of 25-hydroxyvitamin D-3 [25(OH)D-3] is a diagnostic index for vitamin D deficiency/insufficiency, which is associated with a wide range of diseases, such as rickets, cancer and diabetes. We have reported that the derivatization with 4-(4-dimethylaminopheny1)-1,2,4-triazoline-3,5-dione (DAPTAD) works well in the liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) assay of the serum/plasma 25(OH)D-3 for enhancing the sensitivity and the separation from a potent interfering metabolite, 3-epi-25-hydroxyvitamin D-3 [3-epi-25(OH)D-3]. However, enhancing the analysis throughput remains an issue in the LC/ESI-MS/MS assay of 25(OH)D-3. The most obvious restriction of the LC/MS/MS throughput is the chromatographic run time. In this study, we developed an enhanced throughput method for the determination of the plasma 25(OH)D-3 by LC/ESI-MS/MS combined with the derivatization using the triplex (H-2(0)-, H-2(3)- and H-2(6)-) DAPTAD isotopologues. After separate derivatization with 1 of 3 different isotopologues, the 3 samples were combined and injected together into LC/ESI-MS/MS. Based on the mass differences between the isotopologues, the derivatized 25(OH)D-3 in the 3 different samples were quantified within a single run. The developed method tripled the hourly analysis throughput without sacrificing assay performance, i.e., ease of pretreatment of plasma sample (only deproteinization), limit of quantification (1.0 ng/mL when a 5 mu L-plasma was used), precision (intra-assay RSD <<= 5.9% and inter-assay RSD <= 5.5%), accuracy (98.7-102.2%), matrix effects, and capability of separating from an interfering metabolite, 3-epi-25(OH)D-3. The multiplexing of samples by the isotopologue derivatization was applied to the analysis of plasma samples of healthy subjects and the developed method was proven to have a satisfactory applicability. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据