期刊
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
卷 140, 期 -, 页码 334-341出版社
ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpba.2017.03.047
关键词
Volumetric absorptive microsampling; Therapeutic drug monitoring; LC-MS/MS; Hydroxychloroquine; Dried blood spot; Rheumatoid arthritis
A novel technique for collection of capillary blood, termed volumetric absorptive microsampling (VAMS), has been recently cleared by the FDA for collection of human blood. VAMS absorbs a fixed volume of blood (10 I) and overcomes area bias and homogeneity issues associated with dried blood spot (DBS). This study is the application of VAMS for therapeutic drug monitoring (TDM) in human capillary blood. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) workflow for analysis of VAMS samples was developed and validated. Concentrations of hydroxychloroquine (HCQ) and its metabolites, desethylhydroxychloroquine (DHCQ), desethylchloroquine (DCQ), and bisdesethylchloroquine (BDCQ), in capillary blood on VAMS samplers were compared to those in venous blood in rheumatoid arthritis patients. Feasibility of capillary blood collected on both VAMS and DBS cards were evaluated on patients. Stability of dried capillary blood on VAMS was also examined. Our results established that VAMS is a simple and accurate sampling technique that delivers the benefits of DBS sampling while overcoming the issues associated with hematocrit and homogeneity. It requires a small blood volume, simplifies sample logistics management, and may allow sample collection in the patient's home setting. (C) 2017 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐