4.7 Article

Pressure-controlled microfluidic sub-picoliter ultramicro-volume syringes based on integrated micro-nanostructure arrays

期刊

LAB ON A CHIP
卷 19, 期 20, 页码 3368-3374

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c9lc00730j

关键词

-

资金

  1. National Natural Science Foundation of China [21774043, 21975098, 51505456, 61727813]
  2. State Key Laboratory of Applied Optics and Doctor Interdisciplinary Research Funding Scheme of Jilin University

向作者/读者索取更多资源

Ultramicro-volume syringes were fabricated by integrating micro-nanostructure arrays in microchannels for quantitatively dispensing sub-picoliter volumes of liquids. Using this system, liquids were dispensed in volume increments as low as 0.5 pL with 96% accuracy. Specifically, the controllable synthesis of nanocrystals was achieved using a lab-on-chip platform that was integrated with the syringes.