The physiological strain incurred during electrical utilities work over consecutive work shifts in hot environments: A case report

期刊

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/15459624.2017.1365151

关键词

Climate change; heat exposure; heat waves; occupational heat stress; workers

资金

  1. Ontario Ministry of Labour
  2. Electric Power Research Institute

向作者/读者索取更多资源

Purpose: In this article, we evaluated physiological strain in electrical utilities workers during consecutive work shifts in hot outdoor conditions. Methods: Four highly experienced electrical utilities workers were monitored during regularly scheduled-work performed in hot conditions (similar to 34 degrees C) on two consecutive days. Worker hydration (urine specific gravity) was assessed prior to and following work. The level of physical exertion was determined by video analysis. Body core temperature (T-core) and heart rate (HR; presented as a percentage of maximum, % HRmax) were monitored continuously. Responses were reported for each worker individually and as a group mean +/- standard deviation. Results: According to current guidelines, all workers were dehydrated prior to work on both days (urine specific gravity: day 1, 1.025 +/- 0.005; day 2, 1.029 +/- 0.004) and remained dehydrated following work (urine specific gravity: day 1, 1.027 +/- 0.015; day 2, 1.032 +/- 0.004) except for one worker on day 1 (urine specific gravity of 1.005). On day 1, the proportion of the work shift spent at rest (as defined by the American Conference for Governmental and Industrial Hygienists, ACGIH) was 51 +/- 15% (range: 30-64%). Time spent resting increased in all workers on the second day reaching 66 +/- 5% (range: 60-71%) of the work shift. Work shift average T-core was 37.6 +/- 0.1 degrees C (range: 37.5-37.7 degrees C) and 37.7 +/- 0.2 degrees C (range: 37.5-37.9 degrees C) on days 1 and 2, respectively. Peak T-core surpassed the ACGIH recommended threshold limit of 38.0 degrees C for work in the heat in three workers on day 1 (38.1 +/- 0.2 degrees C, range: 37.8-38.2 degrees C) while all workers exceeded this threshold on day 2 (38.4 +/- 0.2 degrees C, range: 38.2-38.7 degrees C). By contrast, work shift average (day 1, 67 +/- 7% HRmax, range: 59-74% HRmax; day 2, 65 +/- 4% HRmax, range: 60-70% HRmax) and peak (day 1, 90 +/- 6% HRmax, range: 83-98% HRmax; day 2, 87 +/- 10% HRmax, range: 73-97% HRmax) HR were similar between days. Conclusion: This case report demonstrates elevations in thermal strain over consecutive work shifts despite decreases in work effort in electrical utilities workers during regular work in the heat.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据