4.7 Article

Improved Estrogen Receptor Assessment by PET Using the Novel Radiotracer 18F-4FMFES in Estrogen Receptor-Positive Breast Cancer Patients: An Ongoing Phase II Clinical Trial

期刊

JOURNAL OF NUCLEAR MEDICINE
卷 59, 期 2, 页码 197-203

出版社

SOC NUCLEAR MEDICINE INC
DOI: 10.2967/jnumed.117.194654

关键词

recepor PET imaging; ER; breast cancer; F-18-FES; F-18-4FMFES

资金

  1. Canadian Breast Cancer Foundation (CBCF)
  2. Fonds de la Recherche du Quebec-Sante (FRQ-S)

向作者/读者索取更多资源

After encouraging preclinical and human dosimetry results for the novel estrogen receptor (ER) PET radiotracer 4-fluoro-11 beta W-methoxy-16 alpha-F-18-fluoroestradiol (F-18-4FMFES), a phase II clinical trial was initiated to compare the PET imaging diagnostic potential of F-18-4FMFES with that of 16-F-18-fluoroestradiol (F-18-FES) in ER-positive(ER+) breast cancer patients. Methods: Patients diagnosed with ER+ breast cancer (n = 31) were recruited for this study, including 6 who underwent mastectomy or axillary node dissection. For each patient, F-18-FES and F-18-4FMFES PET/CT scans were done sequentially (within a week) and in random order. One hour after injection of either radiotracer, a head-to-thigh static scan with a 2-min acquisition per bed position was obtained. Blood samples were taken at different times after injection to assess each tracer metabolism by reverse phase thin-layer chromatography. The SUVmean of nonspecific tissues and the SUVmax of the tumor were evaluated for each detected lesion, and tumor-to-nonspecific organ ratios were calculated. Results: Blood metabolite analysis 60 min after injection of the tracer showed a 2.5-fold increase in metabolic stability of F-18-4FMFES over F-18-FES. Although for most foci F-18-4FMFES PET had an SUVmax similar to that of F-18-FES PET, tumor contrast improved substantially in all cases. Lower uptake was consistently observed in nonspecific tissues for F-18-4FMFES, notably a 4-fold decrease in blood-pool activity as compared with F-18-FES. Consequently, image quality was considerably improved using F-18-4FMFES, with lower overall background activity. As a result, F-18-4FMFES successfully identified 9 more lesions than F-18-FES. Conclusion: This phase II study with ER+ breast cancer patients showed that F-18-4FMFES PET achieves a lower nonspecific signal and better tumor contrast than F-18-FES PET, resulting in improved diagnostic confidence and lower false-negative diagnoses.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据