4.6 Article

Intraoperative electrocorticography for physiological research in movement disorders: principles and experience in 200 cases

期刊

JOURNAL OF NEUROSURGERY
卷 126, 期 1, 页码 122-131

出版社

AMER ASSOC NEUROLOGICAL SURGEONS
DOI: 10.3171/2015.11.JNS151341

关键词

deep brain stimulation; electrocorticography; movement disorders; brain oscillations; primary motor cortex; Parkinson's disease; functional neurosurgery

资金

  1. Bachmann-Strauss Dystonia & Parkinson Foundation [MJFF Research-RRIA 2011]
  2. National Institutes of Health [R01 NS069779]

向作者/读者索取更多资源

OBJECTIVE Contemporary theories of the pathophysiology of movement disorders emphasize abnormal oscillatory activity in basal ganglia-thalamocortical loops, but these have been studied in humans mainly using depth recordings. Recording from the surface of the cortex using electrocorticography (ECoG) provides a much higher amplitude signal than depth recordings, is less susceptible to deep brain stimulation (DBS) artifacts, and yields a surrogate measure of population spiking via broadband gamma (50-200 Hz) activity. Therefore, a technical approach to movement disorders surgery was developed that employs intraoperative ECoG as a research tool. METHODS One hundred eighty-eight patients undergoing DBS for the treatment of movement disorders were studied under an institutional review board approved protocol. Through the standard bur hole exposure that is clinically indicated for DBS lead insertion, a strip electrode (6 or 28 contacts) was inserted to cover the primary motor or prefrontal cortical areas. Localization was confirmed by the reversal of the somatosensory evoked potential and intraoperative CT or 2D fluoroscopy. The ECoG potentials were recorded at rest and during a variety of tasks and analyzed offline in the frequency domain, focusing on activity between 3 and 200 Hz. Strips were removed prior to closure. Postoperative MRI was inspected for edema, signal change, or hematoma that could be related to the placement of the ECoG strip. RESULTS One hundred ninety-eight (99%) strips were successfully placed. Two ECoG placements were aborted due to resistance during the attempted passage of the electrode. Perioperative surgical complications occurred in 8 patients, including 5 hardware infections, 1 delayed chronic subdural hematoma requiring-evacuation, 1 intraparenchymal hematoma, and 1 venous infarction distant from the site of the recording. None of these appeared to be directly related to the use of ECoG. CONCLUSIONS lntraoperative ECoG has long been used in neurosurgery for functional mapping and localization of seizure foci. As applied during DBS surgery, it has become an important research tool for understanding the brain networks in movement disorders and the mechanisms of therapeutic stimulation. In experienced hands, the technique appears to add minimal risk to surgery.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据