4.0 Article

Small-Size vs Large-Size Burr for Rotational Atherectomy

期刊

JOURNAL OF INVASIVE CARDIOLOGY
卷 31, 期 6, 页码 183-186

出版社

H M P COMMUNICATIONS

关键词

access site; bleeding; femoral; radial; transradial; Rotablator; rotational atherectomy

向作者/读者索取更多资源

Background. Rotational atherectomy (RA) has been traditionally performed via the transfemoral approach, mostly utilizing large guide catheters (>= 7 Fr), which can accommodate the passage of large burrs (>= 1.75 mm). However, contemporary data show that using smaller sheath and catheter sizes reduces the risk of procedural access-site related complications. Therefore, the aim of this study was to assess the feasibility of performing RA using smaller burrs and subsequently smaller-sized sheath catheters. Methods. A total of 220 patients underwent RA procedures between January 2011 and July 2017. We compared 162 patients who underwent RA using a maximal burr size of 1.5 mm (small-burr group) with 58 patients who underwent RA using burrs >1.5 mm in diameter (large-burr group). Clinical, procedural, safety, and feasibility data were evaluated and compared between the two groups. Results. Baseline characteristics of the two groups were quite similar other than a higher prevalence of smoking (21.0% vs 5.2%; P<.01) and a lower body weight (80.9 +/- 17.5 kg vs 86.8 +/- 17.2 kg; P=.03) in the small-burr group vs the large-burr group. The indications for the procedure for the small-burr group vs large-burr group were stable angina in 53% vs 62%, unstable angina in 16% vs 17%, non-ST elevation myocardial infarction (MI) in 26% vs 17%, and ST-elevation MI in 3.7% vs 3.4%, respectively (P=NS for all). The target-vessel (TV) diameter was significantly larger in the large-burr group vs the small-burr group (3.5 +/- 0.3 mm vs 3.2 +/- 0.5 mm, respectively; P<.01). Importantly, a sheath size >6 Fr was used in 56.0% of the small-burr group vs 89.5% of the large-burr group (P<.01). Moreover, in 53% of the small-burr group, a guide catheter >6 Fr was used. Radial access was used in 33% of the small-burr group and 17% of the large-burr group (1 ) =.03). Procedural success was achieved in 93% of the small-burr group and 100% of the large-burr group (P=.07). Conclusion. In the majority of cases, RA can be successfully performed using smaller-sized burrs while achieving a high procedural success rate. Notably, our study also highlights the overuse of large sheaths and catheters to deliver small burrs. These results further support the contemporary strategy of using 6 Fr guide catheters, thereby increasing the possibility of using the radial approach for more complex interventional procedures.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据