3.8 Article

Prevalence of 'one and done' in adenoma detection rates: results from the New Hampshire Colonoscopy Registry

期刊

ENDOSCOPY INTERNATIONAL OPEN
卷 7, 期 11, 页码 E1344-E1354

出版社

GEORG THIEME VERLAG KG
DOI: 10.1055/a-0895-5410

关键词

-

资金

  1. American Cancer Society
  2. Norris Cotton Cancer Center Developmental Fund
  3. National Cancer Institute, National Institutes of Health (NCI/NIH) [R01CA131141, R21CA191651, HHSN261201400595P]
  4. Norris Cotton Cancer Center
  5. Centers for Disease Control and Prevention's National Program of Cancer Registries (NPCR) [U58/DP000798]
  6. Dartmouth Clinical and Translational Science Institute from the National Center for Advancing Translational Sciences (NCATS) of the National Institutes of Health (NIH) [UL1TR001086]

向作者/读者索取更多资源

Background and study aims Adenoma detection rate (ADR), the proportion of an endoscopist's screening colonoscopies in which at least one adenoma is found, is an established quality metric. Several publications have suggested that a technique referred to as one and done, where less attention is paid to additional polyp detection following discovery of one likely adenoma, may be occurring 1 2 3 . To investigate whether this practice occurs and provide additional context to the significance of ADR, we examined ADR by single and multiple adenomas in the statewide New Hampshire Colonoscopy Registry (NHCR). Patients and methods A total of 25,324 NHCR patients receiving screening colonoscopies between 2009 and 2014 by 69 endoscopists were analyzed. ADR was dichotomized into high (>= 20 %) and low (< 20 %) based on 2006 recommended targets in place during the time of the study. ADR-plus (the average number of adenomas in colonoscopies with > 1 adenoma) was dichotomized at mean values into high (>= 1.5) and low (< 1.5). As suggested by others, a high ADR but low ADR-plus was used to indicate the one and done approach. Results Among endoscopists with an ADR >= 20 %, only 5 (7.2 %) had low ADR-plus values and were classified as one and done. Results for serrated polyp detection were similar. ADR and ADR-plus decreased monotonically with increasing years since residency ( P values for trend ADR = 0.02; ADR-plus = 0.003) after adjusting for patient risk factors. Conclusion One and done infrequently occurred among endoscopists with high ADR in a large statewide registry. The need to replace ADR with other polyp detection metrics (such as ADR-plus) to accurately ascertain performance quality is not supported by these findings.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据