4.3 Article

Most probable number - loop mediated isothermal amplification (MPN-LAMP) for quantifying waterborne pathogens in <25 min

期刊

JOURNAL OF MICROBIOLOGICAL METHODS
卷 132, 期 -, 页码 27-33

出版社

ELSEVIER
DOI: 10.1016/j.mimet.2016.11.010

关键词

Loop-mediated isothermal amplification; Most probable number; Propidium monoazide; Detection limit; Point-of-care diagnostics

资金

  1. U.S. Environmental Protection Agency [RD83301001, EPD10016]
  2. Michigan Economic Development Corporation [06-1-P1-0557]
  3. National Institute of Environmental Health Sciences Superfund Basic Research Program [NIEHS SBRP P42ES04911]
  4. EPA [EPD10016, 673331] Funding Source: Federal RePORTER

向作者/读者索取更多资源

We are reporting a most probable number approach integrated to loop mediated isothermal technique (MPN-LAMP) focusing on Gram-negative Escherichia coli and Gram-positive Enterococcus faecalis bacterial cells without nucleic acids extraction. LAMP assays for uidA from E. coli and gelE from E. faecalis were successfully performed directly on cells up to single digit concentration using a commercial real time PCR instrument. Threshold time values of LAMP assays of bacterial cells, heat treated bacterial cells (95 degrees C for 5 min), and their purified genomic DNA templates were similar, implying that amplification could be achieved directly from bacterial cells at 63 degrees C. Viability of bacterial cells was confirmed by using propidium monoazide in a LAMP assay with E. faecalis. To check its functionality on a microfluidic platform, MPN-LAMP assays targeting <10 CFU of bacteria were also translated onto polymeric microchips and monitored by a low-cost fluorescence imaging system. The overall system provided signal-to-noise (SNR) ratios up to 800, analytical sensitivity of <10 CFU, and time to positivity of about 20 min. MPN-LAMP assays were performed for cell concentrations in the range of 105 CFU to <10 CFU. MPN values from LAMP assays confirmed that the amplifications were from <10 CFU. The method described here, applicable directly on cells at 63 degrees C, eliminates the requirement of complex nucleic acids extraction steps, facilitating the development of sensitive, rapid, low-cost, and field-deployable systems. This rapid MPN-LAMP approach has the potential to replace conventional MPN method for waterborne pathogens. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据