4.7 Article

Detection of Refractive Index Change From the Critical Wavelength of an Etched Few Mode Fiber

期刊

JOURNAL OF LIGHTWAVE TECHNOLOGY
卷 35, 期 13, 页码 2593-2597

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JLT.2017.2689818

关键词

Critical wavelength; few mode fiber; in-line Mach-Zehnder interferometer; optical fiber sensors; refractive index sensor

资金

  1. National Natural Science Foundation of China [61077031]
  2. Fujian Provincial Department of Science and Technology [2014H6027]
  3. Bureau of Science and Technology of Xiamen [3502Z20141049]

向作者/读者索取更多资源

A novel scheme for the detection of refractive index change based on the mode interference in a special few mode fiber (FMF) is proposed in this paper. The parameters and index profile of the FMF used in the measurement are specifically designed so that only LP01 and LP02 modes are transmitted within the operation wavelength, and the propagation constant difference Delta beta between these two modes reaches maximum at critical wavelength (CWL). An inline Mach-Zehnder interferometric sensor for the detection of surrounding refractive index (SRI) is constructed by splicing FMF with two sections of conventional single mode fiber. We demonstrated at the first time that the CWL will change monotonically with the change of SRI in the measurement range of 1.316-1.439. The experimental sensitivity of the CWL increases with the increase of SRI. A sensitiviy of 140.626 +/- 12.560 nm/RIU in the range of 1.316-1.383 and a maximum sensitivity of 2489.796 +/- 190.179 nm/RIU in the range of 1.433-1.439 were obtained, respectively, in the experiment. At present parameters of the etched FMF, the limit of detection of the refractive index is 3.413 x 10(-4) RIU in the SRI range of 1.316-1.383, and 1.928 x 10(-5) RIU in the SRI range of 1.433-1.439, respectively. The detection of SRI via monitoring the shift of CWL is superior to the traditional detection method via monitoring merely the shift of peak or dip wavelength of the transmission spectrum, since the latter usually suffers from limited measurement range and multivalue problem because it is difficult to identify and follow one specific peak or dip from the transmission spectrum especially if the system needs to reset in practical application. The novel detection scheme based on monitoring the shift of the exclusive CWL of FMF is promising in practical applications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据