4.3 Article

Test of Ultra Fast Silicon Detectors for the TOTEM upgrade project

期刊

JOURNAL OF INSTRUMENTATION
卷 12, 期 -, 页码 -

出版社

IOP PUBLISHING LTD
DOI: 10.1088/1748-0221/12/03/P03024

关键词

Analogue electronic circuits; Performance of High Energy Physics Detectors; Solid state detectors; Timing detectors

资金

  1. Czech Ministry of Education Youth and Sports [LM2015058]
  2. European Union's Horizon Research and Innovation [654168, 669529]
  3. Italian Ministero degli Affari Esteri
  4. INFN Gruppo I and V
  5. National program of sustainability Rice-Netesis of the Ministry of Education, Youth and Sports, Czech Republic [LO1607]
  6. European Research Council (ERC) [669529] Funding Source: European Research Council (ERC)

向作者/读者索取更多资源

This paper describes the performance of a prototype timing detector, based on 50 mu m thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the pixel capacitance and bias voltage is investigated in this paper. A timing precision from 30 ps to 100 ps (RMS), depending on the pixel capacitance, has been measured at a bias voltage of 180 V.