4.7 Article

Energy performance and thickness optimization of hemp wool insulation and air cavity layers integrated in Moroccan building walls'

期刊

SUSTAINABLE PRODUCTION AND CONSUMPTION
卷 20, 期 -, 页码 273-288

出版社

ELSEVIER
DOI: 10.1016/j.spc.2019.07.008

关键词

Hemp wool; Optimum insulation thickness; Optimum air gap thickness; Energy savings; Cooling and heating transmission loads; Life-cycle cost

向作者/读者索取更多资源

Interest in the use of bio-based materials for thermal insulation of buildings has been increasing in recent years. Indeed, the integration of these materials into building envelopes will simultaneously reduce energy use and greenhouse gas (GHG) emission rates. In this context, the thermal performance of bio-based insulation materials is studied and compared to that of conventional insulation materials. However, the majority of these studies, concentrated especially in Europe, lack economic analysis. Cultivated for centuries in Morocco, the use of hemp in the building industry is very limited. The aim of this study is to assess the use of hemp as insulation material for Moroccan external building walls located in Meknes, a city characterized by the Mediterranean climate Csa. Firstly, time lag and decrement factor are investigated in order to assess the dynamic thermal behavior of an external multilayer wall insulated with hemp wool. Afterwards, based on a life cycle cost analysis (LCCA), optimum hemp wool thickness, energy savings and payback period are determined for an analysis period of 20 years. Using a computer program developed in Matlab, an implicit finite difference method is applied to solve the 1D heat equation and investigations are carried out for different wall orientations. It was found that highest optimum insulation thicknesses are provided by east and west orientations (5 cm) followed by the southern and the northern ones (4 and 3 cm, respectively). In addition, an air gap layer is introduced to the optimal insulated multilayer wall, and a third investigation is conducted. The optimal air gap thickness is determined based on the analysis of various thermal parameters such as Prandtl, Rayleigh and Nusselt numbers, conduction, convection and radiation heat transfer rates. For all wall orientations, optimum air gap thickness was found equal to 1.3 cm. Annual GHG emissions were also calculated and it was found that they can be decreased by about 71% with the use of optimum thicknesses of hemp wool and air cavity insulations. Finally, a comparative study with the recommendations set by the Moroccan thermal regulation is conducted. The findings showed that our investigated configuration would be more efficient from thermal, economical and environmental points of view. (C) 2019 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据