Analysis of a GaN-Based CRM Totem-Pole PFC Converter Considering Current Sensing Delay

出版社

IEEE
DOI: 10.1109/ecce.2019.8912203

关键词

GaN; CRM; totem-pole PFC; soft switching; zero current detection (ZCD); current sensing delay

资金

  1. Intel Corporation
  2. Engineering Research Center Program of the National Science Foundation
  3. DOE under NSF [EEC-1041877]
  4. CURENT Industry Partnership Program

向作者/读者索取更多资源

High-frequency soft-switched gallium-nitride (GaN) based critical conduction mode (CRM) totem-pole power factor correction (PFC) converter is one of the most potential candidates in data center power supplies. However, the high-speed cycle-by-cycle zero current detection (ZCD) brings challenges to zero-voltage-switching (ZVS) control. Current sensing delay (CSD) exists, and the ZCD circuit is sensitive to high dv/dt switching noise. In this paper, mechanisms of the ZCD time error are elaborated, and impacts of the current sensing delay on converter switching frequency, inductor current, input current third harmonic distortion (THD), and power loss are analyzed. Qualification time is added within the controller for immunity to the swiching noise, and a CSD embedded converter model is proposed to compensate the ZCD time delay. Also, loss modeling of the CRM totem-pole PFC is conducted to aid in analysis of the proposed theory. A 1.5 kW single-phase CRM totem-pole PFC prototype is tested. Experimental results validiate the analysis, modeling, and the proposed compensation method for current sensing delay.