4.7 Article

Development and characterization of an electrochemical biosensor for creatinine detection in human urine based on functional molecularly imprinted polymer

期刊

JOURNAL OF ELECTROANALYTICAL CHEMISTRY
卷 788, 期 -, 页码 44-53

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.jelechem.2017.01.068

关键词

Molecular imprinted polymer (MIP); Screen-printed gold electrodes; Creatinine; Biosensor; Human urine

资金

  1. European Commission under the Horizon Program of the European Union, project TROPSENSE [645758]
  2. Moulay Ismail University (project Appui a la recherche)

向作者/读者索取更多资源

In this work, sensor based on a new molecularly imprinted polymer (MIP) for creatinine (Cre) detection, using screen-printed gold electrodes (Au-SPE), was developed. A carboxylic polyvinyl chloride (PVC-COOH) layer was first deposited on Au-SPE surface. The creatinine molecules were attached to the surface of Au-SPE/PVCCOOH. Afterward, the polymerization of acrylamide and N, N' methylenebisacrylamid filled vacant spaces around them. The subsequent templates removal left binding sites within the polymer which are capable of selectively recognizing creatinine at different concentrations. To test the sensitivity of this biosensor, the same procedure without creatinine was performed on a gold non-imprinted polymer (Au-SPE/NIP). Their retention and molecular-recognition properties were qualitatively investigated by means of three instrumental techniques: voltammetry (cyclic voltammetry (CV) and differential pulse voltammetry (DPV)), electrochemical impedance spectroscopy (EIS), and UV-Visible spectrophotometry (UV-Vis). The obtained results indicate that the MIP had a specific recognition ability for creatinine, while other structurally related compounds, such as urea or glucose, could not be recognized on the MIP. In addition, the biosensor was tested on volunteers with different creatinine urine levels and seemed a promising tool for screening creatinine in point-of-care. Moreover, Partial Least Square (PLS) analysis was used to obtain a correlation between the predicted creatinine concentrations from voltammetric measurements and concentrations measured by Jaffe's reaction as a reference method. The EIS and DPV biosensor responses show a limit of detection of 0.016 ng/mL and 0.081 ng/mL, respectively, with a linear range from 0.1 ng/mL to 1 mu g/mL. This study provides a promising strategy to fabricate sensor devices based on MIP with highly selective recognition ability, simplicity of operation, small size and low cost. Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据