期刊
DESALINATION AND WATER TREATMENT
卷 57, 期 44, 页码 21054-21061出版社
DESALINATION PUBL
DOI: 10.1080/19443994.2015.1119745
关键词
Reject water; Nitrification; Denitrification; Autohydrogenotrophic denitrification; Bio-electrochemical; Pumparound system
资金
- University of Malaya [RG 077/ 09 SUS]
In this study, a modified twin chamber up-flow bioelectrochemical reactor (TCUBER) was investigated during sequential bioelectrochemical nitrification and denitrification of reject water experimentally. A twin chamber up-flow bioelectrochemical pump-around system (TCUBEPS) makes it possible to investigate the effects of different pH values (6.5 +/- 0.1, 7.5 +/- 0.1, 8.5 +/- 0.1, and 9.5 +/- 0.1) on the system efficiency at different applied current intensities (I=20-50mA) and HRT (6-24h) values. The results show that the pump-around system succeeded to stabilize the pH and the most favorable values of pH for the activation of nitrifying and denitrifying bacteria in both compartments were 7.5 and 8.5, respectively, whereas the removal percentage of NH4-N was 96% at higher applied HRT (24h) and constant I (50mA). This study contributed to a better understanding of the function of variables, namely HRT, pH, and I to treat reject water with high concentration of ammonium.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐