期刊
MINING METALLURGY & EXPLORATION
卷 37, 期 2, 页码 773-781出版社
SPRINGER HEIDELBERG
DOI: 10.1007/s42461-019-00153-0
关键词
Refuge alternative; Underground mine; Heat stress
Heat and humidity buildup withn refuge alternatives (RAs) may expose occupants to physiological hazards such as heat stress. The Mine Safety and Health Administration (MSHA) regulations require RAs in underground coal mines to provide a life-sustaining environment for miners trapped underground when escape is impossible. RAs are required to sustain life for 96 h while maintaining an apparent temperature (AT) below 95 degrees F (35 degrees C). The National Institute for Occupational Safety and Health (NIOSH) tested a 10-person tent-type RA, a 23-person tent-type RA, and a 6-person metal-type RA in its underground coal mine facilities to investigate the thermal environment over a 96-h period. The test results showed that mine air and mine strata temperatures surrounding an RA occupied by simulated miners (SMs) increased over the 96-h test period. The test results suggest that RA manufacturers should consider this increase in temperatures when calculating and evaluating RA components during surface and laboratory tests. The findings can equip stakeholders with additional considerations for calculating the interior heat and humidity temperature profiles for occupied RAs not tested in situ.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐