4.5 Article

Removal of bacterial and viral indicator organisms in full-scale aerobic granular sludge and conventional activated sludge systems

期刊

WATER RESEARCH X
卷 6, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.wroa.2019.100040

关键词

Aerobic granular sludge; Activated sludge; Faecal indicators; F-specific RNA bacteriophages; Pathogen removal

资金

  1. Royal HaskoningDHV, Amersfoort, The Netherlands
  2. Technological Institute of Costa Rica [007-2014-M]

向作者/读者索取更多资源

The aim of this study was to evaluate the effectiveness of the novel aerobic granular sludge (AGS) wastewater treatment technology in removing faecal indicator organisms (FIOs) compared to the conventional activated sludge (CAS) treatment system. The work was carried out at two full-scale wastewater treatment plants (WWTP) in the Netherlands, Vroomshoop and Garmerwolde. Both treatment plants have a CAS and AGS system operated in parallel. The parallel treatment lines are provided with the same influent wastewater. The concentrations of the measured FIOs in the influent of the two WWTPs were comparable with reported literature values as follows: F-specific RNA bacteriophages at 10(6) PFU/100 mL, and Escherichia coli (E. coli), Enterococci, and Thermotolerant coliforms (TtC) at 10(5) to 10(6) CFU/100 mL. Although both systems (CAS and AGS) are different in terms of design, operation, and microbial community, both systems showed similar FIOs removal efficiency. At the Vroomshoop WWTP, Log(10) removals for F-specific RNA bacteriophages of 1.4 +/- 0.5 and 1.3 +/- 0.6 were obtained for the AGS and CAS systems, while at the Garmerwolde WWTP, Log(10) removals for F-specific RNA bacteriophages of 1.9 +/- 0.7 and 2.1 +/- 0.7 were found for the AGS and CAS systems. Correspondingly, E. coli, Enterococci, and TtC Log(10) removals of 1.7 +/- 0.7 and 1.1 +/- 0.7 were achieved for the AGS and CAS systems at Vroomshoop WWTP. For Garmerwolde WWTP Log(10) removals of 2.3 +/- 0.8 and 1.9 +/- 0.7 for the AGS and CAS systems were found, respectively. The measured difference in removal rates between the plants was not significant. Physicochemical water quality parameters, such as the concentrations of organic matter, nutrients, and total suspended solids (TSS) were also determined. Overall, it was not possible to establish a direct correlation between the physicochemical parameters and the removal of FIOs for any of the treatment systems (CAS and AGS). Only the removal of TSS could be positively correlated to the E. coli removal for the AGS technology at the evaluated WWTPs. (c) 2019 The Authors. Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据