4.5 Article

Constraining the accuracy of flux estimates using OTM 33A

期刊

ATMOSPHERIC MEASUREMENT TECHNIQUES
卷 13, 期 1, 页码 341-353

出版社

COPERNICUS GESELLSCHAFT MBH
DOI: 10.5194/amt-13-341-2020

关键词

-

资金

  1. Wyoming School of Energy Resources Center of Excellence in Air Quality
  2. Clean Air Task Force
  3. Methane Emissions Technology Evaluation Center

向作者/读者索取更多资源

Other Test Method 33A (OTM 33A) is a nearsource flux measurement method developed by the Environmental Protection Agency (EPA) primarily used to locate and estimate emission fluxes of methane from oil and gas (O&G) production facilities without requiring site access. A recent national estimate of methane emissions from O&G production included a large number of flux measurements of upstream O&G facilities made using OTM 33A and concluded the EPA National Emission Inventory underestimates this sector by a factor of similar to 2.1 (Alvarez et al., 2018). The study presented here investigates the accuracy of OTM 33A through a series of test releases performed at the Methane Emissions Technology Evaluation Center (METEC), a facility designed to allow quantified amounts of natural gas to be released from decommissioned O&G equipment to simulate emissions from real facilities (Fig. 1). This study includes test releases from single and multiple points, from equipment locations at different heights, and spanned methane release rates ranging from 0.16 to 2.15 kg h(-1). Approximately 95% of individual measurements (N = 45) fell within +/- 70% of the known release rate. A simple linear regression of OTM 33A versus known release rates at the METEC site gives an average slope of 0.96 with 95% CI (0.66, 1.28), suggesting that an ensemble of OTM 33A measurements may have a small but statistically insignificant low bias.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据